FLOAT SWITCH SOBA EX ATEX ATMI

FLOAT SWITCH SOBA EX ATEX ATMI

SOBA EX ATEX Certified
FLOAT LEVEL REGULATOR
For automatic regulation with several devices


APPLIANCES :
Same applications as the SOBA HR HY model. However, it is especially designed for working in explosive
gas areas : solvents, hydrocarbons, alcohols, chemical and pharmaceutical products
Operation mode :
Allowed fluid density : 0,80 a 1,10
Maximum pressure : 4 bars
Maximum temperature : Ta: from -20°C to +70°C / idem
Protection index : IP 68
Electric characteristics : 24 VAC/VDC – 10 mA or 12 VAC/VDC – 100 Ma
Obligatory connection With intrinsic safety relay
Microswitch : Gold plated reverser contacts
Biconical shell (2) Copolymer polypropylene + HR HY (hypalon)
Cable : HR HY (hypalon) H07RN-F
Cable type : 3 conductors 1 mm²
Float weight without cable : 300 g
Cable weight Neoprene : 115 g/m – HR HY 110 g/m
Adjustable ballast on cable (series) : Loaded resin 250 g


SOBA EX ATEX FLOAT LEVEL REGULATOR ATMI

SOBA EX ATEX FLOAT LEVEL REGULATOR ATMI.

SOBA EX ATEX Certified
FLOAT LEVEL REGULATOR
For automatic regulation with several devices


APPLIANCES :
Same applications as the SOBA HR HY model. However, it is especially designed for working in explosive
gas areas : solvents, hydrocarbons, alcohols, chemical and pharmaceutical products
Operation mode :
Allowed fluid density : 0,80 a 1,10
Maximum pressure : 4 bars
Maximum temperature : Ta: from -20°C to +70°C / idem
Protection index : IP 68
Electric characteristics : 24 VAC/VDC – 10 mA or 12 VAC/VDC – 100 Ma
Obligatory connection With intrinsic safety relay
Microswitch : Gold plated reverser contacts
Biconical shell (2) Copolymer polypropylene + HR HY (hypalon)
Cable : HR HY (hypalon) H07RN-F
Cable type : 3 conductors 1 mm²
Float weight without cable : 300 g
Cable weight Neoprene : 115 g/m – HR HY 110 g/m
Adjustable ballast on cable (series) : Loaded resin 250 g


SOBA SMALL HYPALON FLOAT SWITCH

SOBA SMALL HYPALON FLOAT SWITCH.

SOBA SMALL
FLOAT LEVEL REGULATOR
For automatic regulation with several devices

APPLIANCES :
Suitable for various liquids. Similar to the SOBA but with a smaller size. Especially adapted to small tanks and domestic or collective prefabricated pumping stations. Can be used as an «ALARM» detector. (please, refer to the SOBA technical sheet)
Operation mode :
Allowed fluid density : 0,70 a 1,25    
Maximum pressure : 3,5 bars
Maximum temperature : 85°C
Protection index : IP 68
Electric characteristics : 12, 24, 48 VAC/VDC et 250 VAC- 50/60 Hz
Cut-out power  : 16 (6) A (16 A résistive - 6 A inductive)
Microswitch : Silver / nickel reverser contacts
Biconical shell : Copolymer polypropylene
Cable : Neoprene or HR HY (hypalon) H07RN8-F
Cable type : 3 conductors 1 mm²
Float weight without cable : 110 g
Cable weight Neoprene : 115 g/m – HR HY 110 g/m
Adjustable ballast on cable (series) : Loaded resin 250 g




SOBA SMALL FLOAT LEVEL REGULATOR ATMI

SOBA SMALL FLOAT LEVEL REGULATOR ATMI

SOBA SMALL
FLOAT LEVEL REGULATOR
For automatic regulation with several devices

APPLIANCES :
Suitable for various liquids. Similar to the SOBA but with a smaller size. Especially adapted to small tanks and domestic or collective prefabricated pumping stations. Can be used as an «ALARM» detector. (please, refer to the SOBA technical sheet)
Operation mode :
Allowed fluid density : 0,70 a 1,25    
Maximum pressure : 3,5 bars
Maximum temperature : 85°C
Protection index : IP 68
Electric characteristics : 12, 24, 48 VAC/VDC et 250 VAC- 50/60 Hz
Cut-out power  : 16 (6) A (16 A résistive - 6 A inductive)
Microswitch : Silver / nickel reverser contacts
Biconical shell : Copolymer polypropylene
Cable : Neoprene or HR HY (hypalon) H07RN8-F
Cable type : 3 conductors 1 mm²
Float weight without cable : 110 g
Cable weight Neoprene : 115 g/m – HR HY 110 g/m
Adjustable ballast on cable (series) : Loaded resin 250 g




Cable Float Level Switch MAC5

Cable Float Level Switch MAC5.

MAC5 Italy
Model ( ALPUKAT/AVOCADO )
Float level Switchs For sewage water.

Tilting level regulators were designed specifically for sewage water. Normally used in control panel, for lifting station, the device can be also installed directly on pumps.


Application: It has heavy body, which is also bulky and free of any irregularity, making
it ideal for use in sewage water, in industrial waste water with suspended agglomerate residues and in tumultuous water.
Advantages: Made with a double liquid proof chamber and counter weight built into the body of the float.
Benefits: Available with switch angle standard +/-10° and also with a wider one.
ALSO AVAILABLE VERSION ATEX APPROVED
Microswitch electrical features : 10(3)A 250 V
Approval : ENEC/CE 10(3)A 250V~
Operating Temp. : 0°C · + 50°C
Storage temp. : -10°C · +60°C
Protection rating : IP 68
Switch angle : +/-45° or -/+10°
Dimensions : mm 117x222 (xh)
Volume : cm3 1000
Max depth level : 2 bar
Housing : Non-toxic polypropylene (PP)
Colouring : Non-toxic
Standard cable : PVC 3X1, H07RN-F 3x1, H07RBN-4F 3X1
Note : Disponibile la versione omologata ATEX Available the ATEX approved range



MAC5 Float Switch 5 Meter MAC3

MAC5 Float Switch 5 Meter MAC3

MAC5 Italy
level regulator For sewage water.

Tilting level regulators were designed specifically for sewage water. Normally used in control panel, for lifting station, the device can be also installed directly on pumps.


Application: 
It has heavy body, which is also bulky and free of any irregularity, making
it ideal for use in sewage water, in industrial waste water with suspended agglomerate residues and in tumultuous water.
Advantages: Made with a double liquid proof chamber and counter weight built into the body of the float.
Benefits: Available with switch angle standard +/-10° and also with a wider one.
ALSO AVAILABLE VERSION ATEX APPROVED
Microswitch electrical features : 10(3)A 250 V
Approval : ENEC/CE 10(3)A 250V~
Operating Temp. : 0°C · + 50°C
Storage temp. : -10°C · +60°C
Protection rating : IP 68
Switch angle : +/-45° or -/+10°
Dimensions : mm 117x222 (xh)
Volume : cm3 1000
Max depth level : 2 bar
Housing : Non-toxic polypropylene (PP)
Colouring : Non-toxic
Standard cable : PVC 3X1, H07RN-F 3x1, H07RBN-4F 3X1
Note : Disponibile la versione omologata ATEX Available the ATEX approved range



MAC5 Float Level Regulator Atex

MAC5 Float Level Regulator Atex.

MAC5 Italy

level regulator For sewage water.

Tilting level regulators were designed specifically for sewage water. Normally used in control panel, for lifting station, the device can be also installed directly on pumps.

Application: It has heavy body, which is also bulky and free of any irregularity, making
it ideal for use in sewage water, in industrial waste water with suspended agglomerate residues and in tumultuous water.
Advantages: Made with a double liquid proof chamber and counter weight built into the body of the float.
Benefits: Available with switch angle standard +/-10° and also with a wider one.
ALSO AVAILABLE VERSION ATEX APPROVED
Microswitch electrical features : 10(3)A 250 V
Approval : ENEC/CE 10(3)A 250V~
Operating Temp. : 0°C · + 50°C
Storage temp. : -10°C · +60°C
Protection rating : IP 68
Switch angle : +/-45° or -/+10°
Dimensions : mm 117x222 (xh)
Volume : cm3 1000
Max depth level : 2 bar
Housing : Non-toxic polypropylene (PP)
Colouring : Non-toxic
Standard cable : PVC 3X1, H07RN-F 3x1, H07RBN-4F 3X1
Note : Disponibile la versione omologata ATEX Available the ATEX approved range